What Empirical Rules and Field Practices Matter for Tapered Roller Preload and Clearance?

· Preload setting: cold preload = 70% of calculated value; after warm‑up, if housing temperature rises >40°C, reduce preload.

· Re‑torque after running‑in: after 24 hours, recheck clearance (typically increases by 0.01–0.03 mm).